What Happens If the Cooling Fails: Runaway Reactions and MTSR

Contents
  1. Four temperatures decide the outcome
  2. Step 1: the adiabatic temperature rise
  3. Step 2: how much reaction is still to come
  4. Step 3: place the result in a criticality class
  5. Accumulation is the number to protect
  6. What this assessment does not cover

Every exothermic reactor is designed to remove its heat of reaction. The safety question is what happens when that stops: a pump trips, a cooling water valve sticks, or the power fails. The answer depends on how much heat is still to come and how hot it can make the batch.

This series uses examples from earlier posts. This part takes the 10,000 L reactor from the scale-up series. Post 2 runs a HAZOP on the feed heater from How to Read a PFD and a P&ID, and Post 3 shows how a small change can undo both.

Four temperatures decide the outcome

A cooling failure assessment compares four temperatures. The method is widely used in the fine chemical and pharmaceutical industries and was set out by Francis Stoessel.

Table 1. The four temperatures in a cooling failure assessment

TemperatureMeaningExample
Process temperatureThe normal operating temperature of the batch60 °C
MTSRMaximum temperature of the synthesis reaction: how hot the batch gets if cooling stops and the remaining reactant reactsCalculated below
MTTMaximum temperature for technical reasons. For a reactor open to a condenser, this is the boiling point of the batch110 °C
TD24The temperature at which a decomposition, with no cooling, would take 24 hours to reach its maximum rate. Measured by thermal stability tests150 °C

The first is set by the process. MTT comes from the equipment and the solvent. TD24 comes from laboratory tests on the reaction mixture. MTSR is calculated.

Step 1: the adiabatic temperature rise

If no heat leaves the reactor, all the heat of reaction goes into warming the batch. The rise in temperature is:

ΔTad = heat of reaction ÷ heat capacity = 150 kJ/kg ÷ 2.0 kJ/kg·K = 75 K

The reaction and heat capacity are the ones used in the scale-up series. If the whole reaction could still happen after the cooling fails, the batch would climb 75 K above its starting temperature.

Step 2: how much reaction is still to come

In the plant the reactant is added over three hours, so at any moment only part of it is in the reactor unreacted. That unreacted part is called the accumulation. Only the accumulated reactant can still release heat if the feed stops when the cooling fails.

MTSR = process temperature + accumulation × ΔTad

Reaction calorimetry measures the accumulation during the addition. In the example the highest value is 20%:

MTSR = 60 °C + 0.20 × 75 K = 75 °C

40 °C60 °C80 °C100 °C120 °C140 °C160 °C180 °CTD24, decomposition: 150 °CBoiling point (MTT): 110 °CMTSR 135 °CAll reactant charged at once100% accumulatedMTSR 75 °CAdded over 3 hours20% accumulated at mostProcess 60 °C
Figure 1. The same reaction run two ways. Adding the reactant over three hours keeps the possible temperature rise to 15 K.

Had all the reactant been charged at once, as in a simple lab procedure, the accumulation would be 100% and the MTSR 135 °C. The batch would reach its boiling point.

Step 3: place the result in a criticality class

The order of the four temperatures gives a criticality class from 1 to 5.

Table 2. Criticality classes for a cooling failure

ClassOrder of temperaturesWhat it means
Class 1MTSR < MTT < TD24Neither boiling nor decomposition is reached. Avoid holding the batch hot for long.
Class 2MTSR < TD24 < MTTBoiling is not reached, but decomposition starts below the boiling point. Avoid long holds.
Class 3MTT < MTSR < TD24The batch boils before it can decompose. Condenser and vent must handle boiling at full rate.
Class 4MTT < TD24 < MTSRBoiling comes first, but decomposition can follow. Evaporative cooling must be proven.
Class 5TD24 < MTT, TD24 < MTSRDecomposition starts before boiling. Boiling gives no protection. Change the process.

With the three-hour addition, the example is Class 1: 75 °C is well below both the boiling point and TD24. Charged all at once it would be Class 3. The batch would boil, and the condenser and vent would have to cope with the remaining third of the reaction heat, about 0.5 GJ, boiling off around 1,250 kg of solvent.

Accumulation is the number to protect

The semi-batch result holds only while the reaction keeps up with the feed. If the reaction slows and the feed carries on, unreacted material builds up and the MTSR rises with it.

40 °C60 °C80 °C100 °C120 °C140 °C160 °C0%20%40%60%80%100%Unreacted reactant in the reactor when cooling fails (accumulation)TD24 150 °CBoiling point 110 °CNormal operation: 20%, 75 °CBoiling reached at 67%135 °C
Figure 2. MTSR rises with accumulation. Above 67% the batch could reach its boiling point after a cooling failure.

Table 3. MTSR for different accumulations in the example

AccumulationMTSRClassWhen it could happen
0%60 °CClass 1Reactant consumed as fast as it is added
20%75 °CClass 1Normal operation, measured in calorimetry
40%90 °CClass 1Feed slightly too cold
60%105 °CClass 1Reaction slowed, for example by low temperature or weak catalyst
80%120 °CClass 3Reaction barely running while feed continues
100%135 °CClass 3Reaction never started; all reactant added

The common causes of high accumulation are a feed that is too cold, a reaction that has not started, a missing or weak catalyst, and poor mixing. That gives three practical rules for the plant:

  • Stop the feed when cooling is lost. An interlock on cooling water flow or reactor temperature that stops the feed pump caps the accumulation at its current value.
  • Confirm the reaction has started before adding at full rate. A small first portion, followed by a check that heat is being released, shows the reaction is running.
  • Do not add reactant below the minimum temperature. A cold batch reacts slowly while the feed continues. The HAZOP in Post 2 finds exactly this case on the feed heater.

Try it: cooling failure at your conditions

Set the reaction data and the three limiting temperatures. The calculator gives the MTSR and the criticality class.

Adiabatic temperature rise
MTSR
MTSR against boiling point
Criticality

Figure 3. The four temperatures for your inputs. The coloured bar shows how far the batch could heat up after a cooling failure.

What this assessment does not cover

  • Gas generation. A reaction or decomposition that releases gas can pressurise the reactor well below the temperatures above. Gas release must be measured separately.
  • Relief sizing. A Class 3 or 4 result means the vent must be sized for boiling or two-phase flow. That is a specialist calculation.
  • The data. Heat of reaction, accumulation and TD24 come from calorimetry and thermal stability tests on the actual mixture. Literature values are a starting point only.

To practise the underlying calculations, try the free Reactor Design Exam.

Takeaway. Calculate how hot the batch could get if cooling fails, and compare it with the boiling point and the decomposition temperature. In the example, a three-hour addition with 20% accumulation keeps the MTSR at 75 °C. Charging everything at once would give 135 °C.

The reaction, temperatures and equipment in this series are an illustrative example. The calculations are screening estimates. They do not replace calorimetry testing, a formal hazard study or a design by a qualified engineer.

Keep reading

Related articles

All 151 articles

Process Engineering

Process safety series · Part 2 of 3

A Worked HAZOP: The Feed Heater, Node by Node

A HAZOP of one steam heater: guide words, two nodes, the worksheets, seven actions, and the P&ID before and after the study.

Nov 12, 2026 · 5 min read

Process Engineering

Process safety series · Part 3 of 3

Management of Change for Small Plants

How small changes undo a safe design, with two worked examples, a review scaled to risk and a one-page MOC form for small plants.

Nov 12, 2026 · 5 min read

Ready to find your next improvement?

Book a strategy call. We will talk through your goals, pain points and where AI, systems or process work can make the biggest difference.