A reaction that behaves in a one-litre flask can overheat in a ten-cubic-metre reactor with the same recipe. The chemistry is identical. The geometry has changed, and with it the rate at which the vessel can remove heat and mix its contents.

This series follows one example: an exothermic liquid reaction scaled from a 1 L lab reactor to a 100 L pilot reactor and then to a 10,000 L commercial reactor. This post covers what changes with size. Post 2 covers what the pilot plant must find out, and Post 3 turns the pilot data into a mass and energy balance.

Volume grows faster than surface area

Heat is generated throughout the volume of the liquid and leaves through the wall. When a vessel is made larger in every direction, its volume rises with the cube of the diameter and its wall area with the square. The area available per cubic metre therefore falls as the vessel grows.

Jacket area per unit volume = 4 ÷ diameter  (for a vessel filled to a depth equal to its diameter)

Lab: 1 LDiameter 0.11 m36.9 m² of jacket per m³Pilot: 100 LDiameter 0.50 m8.0 m² of jacket per m³Commercial: 10,000 LDiameter 2.34 m1.7 m² of jacket per m³Cooling jacket on the wall
Figure 1. The same reactor shape at three sizes, not drawn to scale. Each step is 100 times the volume, and the jacket area per cubic metre falls by a factor of 4.6 each time.

From 1 L to 10,000 L the volume increases 10,000 times and the jacket area per cubic metre falls 21.5 times.

Worked example: can the jacket remove the heat?

Suppose the reaction releases 150 kJ for each kilogram of batch. A jacket removes heat at a rate set by three things: the heat transfer coefficient, the wall area and the temperature difference between the batch and the coolant.

Cooling capacity = U × A × ΔT = 300 W/m²·K × A × 30 K

Table 1. Cooling capacity at three scales, for U = 300 W/m²·K and ΔT = 30 K

ScaleVolumeDiameterJacket area per volumeCooling capacityShortest safe reaction time
Lab1 L0.11 m36.9 m²/m³332.1 kW/m³8 min
Pilot100 L0.50 m8.0 m²/m³71.6 kW/m³35 min
Commercial10,000 L2.34 m1.7 m²/m³15.4 kW/m³162 min

The heat to remove is 150 kJ/kg × 1,000 kg/m³ = 150,000 kJ per cubic metre of batch, or 41.7 kWh. If the reaction is run in one hour, as in the lab, the heat is released at 41.7 kW per cubic metre.

kW per m³ of batch (log scale)101001,000332 kW/m³Lab, 1 L71.6 kW/m³Pilot, 100 L15.4 kW/m³Commercial, 10,000 LHeat released when the reaction runs in 1 hour: 41.7 kW/m³
Figure 2. Cooling capacity per cubic metre against the heat released by a one-hour reaction. The lab and pilot reactors have capacity to spare. The commercial reactor does not.

The lab reactor can remove eight times the heat that is generated, and the pilot reactor 1.7 times. The commercial reactor can remove only 15.4 kW/m³ against 41.7 kW/m³ generated. With the lab recipe, its temperature would climb.

The usual answer is to add one reactant gradually, so the reaction can only proceed as fast as the feed arrives. The addition time must then be at least:

41.7 kWh/m³ ÷ 15.4 kW/m³ = 2.7 hours

A one-hour lab procedure becomes an addition of about three hours in the plant. That change affects the batch cycle time, the number of batches a year and the size of the reactor needed for a given output.

Try it: cooling capacity at your scale

Set the reactor volume and the reaction data. The calculator assumes a jacket on the wall only, a liquid depth equal to the diameter and a batch density of 1,000 kg/m³.

Jacket area per volume
Cooling capacityper m³ of batch
Heat release rateat the planned time
Shortest safe addition
Figure 3. Cooling capacity against reactor volume for your inputs. The dashed line is the heat release rate at the planned addition time.

What else changes with size

Heat removal is usually the first limit, and several other quantities change at the same time. The table assumes the same vessel shape and the same agitator power per cubic metre at each scale.

Table 2. How key quantities change from 1 L to 10,000 L

QuantityChanges with1 L to 10,000 LWhat it means in the plant
Jacket area per volume1 ÷ diameter÷ 21.5Less cooling and heating per kilogram of batch
Heat-up and cool-down timeDiameter× 21.5Minutes in the lab become hours
Mixing timeDiameter to the power ⅔× 7.7Added reactant stays concentrated for longer, which can change selectivity
Agitator tip speedDiameter to the power ⅓× 2.8More shear, which matters for crystals, emulsions and cells
Liquid depthDiameter× 21.5Higher pressure at the bottom changes boiling point and gas solubility

No single rule keeps all of these constant. Scale-up means deciding which quantity matters most for the process and holding that one, then checking that the others stay acceptable. Finding out which one matters is the purpose of the pilot plant, covered in Post 2.

Three cautions

  • The heat transfer coefficient is not constant. Thicker walls, glass lining and fouling all lower it at plant scale. Measure it on the pilot reactor and check the vendor's figure for the commercial vessel.
  • Gradual addition only works if the reaction keeps up. If the reactant accumulates unreacted and then reacts all at once, the heat arrives faster than the feed rate suggests. Reaction calorimetry shows whether this can happen.
  • Cooling failure must be assessed separately. This post covers normal operation. The temperature the batch could reach with no cooling at all is a process safety question and needs its own study.

To practise the calculations, try the free Engineering Scale Up Exam I and the Scale Up Calc Exam III.

Takeaway. Cooling capacity per cubic metre falls as the reactor grows. In the example it drops from 332 to 15.4 kW/m³, and a one-hour lab reaction needs at least 2.7 hours of controlled addition at 10,000 L.

The reaction, the vessels and the costs in this series are an illustrative example. The calculations are screening estimates and do not replace process safety testing or a design by a qualified engineer.

Keep reading

Related articles

All 155 articles
Process EngineeringProject Management

Scale-up series · Part 2 of 3

What a Pilot Plant Is For: The Questions It Must Answer

A pilot plant exists to produce design data. Eight questions it should answer, how large to build it, and what to collect before shutting it down.

Nov 11, 2026 · 5 min read

Process EngineeringOperational Efficiency

Scale-up series · Part 3 of 3

From Pilot Data to a Mass and Energy Balance

A worked example that scales a 100 kg pilot batch to a 5,000 t/y plant: mass balance, energy balance, utility loads and variable cost per kilogram.

Nov 11, 2026 · 4 min read

Ready to find your next improvement?

Book a strategy call. We will talk through your goals, pain points and where AI, systems or process work can make the biggest difference.